LZSR Current Transducer Sensors

LEM LZSR Current Transducer Sensors are designed for precise measurement of DC, AC, and pulse currents, ranging from 80ARMS to 200ARMS, while ensuring galvanic isolation between primary and secondary circuits. These sensors offer outstanding performance with ultra-low offset drift as low as 3ppm/K, a significant improvement over previous generations that relied on traditional Hall-effect chips. Additional features include reference access, an overcurrent detection output, and operation on a +5V power supply, making the components highly efficient for various industrial applications.

結果: 8
選擇 圖像 零件編號 製造商 說明 規格書 供貨情況 定價 (HKD) 基於數量按單價篩選表中結果。 數量 RoHS ECAD模型 额定电流 傳感器類型 回應時間 準確性 頻率範圍 工作電源電壓 輸出類型
LEM 板上安裝電流感測器 Current Transducer LZSR 100-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 122庫存量
最少: 1
倍數: 1

100 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM 板上安裝電流感測器 Current Transducer LZSR 150-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 88庫存量
最少: 1
倍數: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM 板上安裝電流感測器 Current Transducer LZSR 150-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 115庫存量
最少: 1
倍數: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM 板上安裝電流感測器 Current Transducer LZSR 150-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 51庫存量
最少: 1
倍數: 1

150 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog
LEM 板上安裝電流感測器 Current Transducer LZSR 80-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 166庫存量
最少: 1
倍數: 1

80 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM 板上安裝電流感測器 Current Transducer LZSR 100-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 57庫存量
最少: 1
倍數: 1

100 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog
LEM 板上安裝電流感測器 Current Transducer LZSR 200-TP/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 27庫存量
最少: 1
倍數: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM 板上安裝電流感測器 Current Transducer LZSR 200-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 37庫存量
最少: 1
倍數: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog